Preparation for Radiant Piping before it is embedded           back home

addsl1 addsl1 addsl1 addsl1 addsl1 addsl1
Insulation downward 2" polystyrene board - to hold the pipe in place - flat meshwire - this will be a 4 inch thick main level slab poured with concrete  Insulation downward with concrete barrier foil adds a reflective layer to the insulation - to hold the pipe in place - flat meshwire - this will be a 4 inch thick basement level slab poured with concrete Insulation downward with  Concrete barrier foil  - to hold the pipe in place - flat meshwire - this will be a 1.5 inch gypcrete over pour slab on slab. Insulation downward with polystyrene board 1 inch - hold the pipe in place - flat meshwire - this will be a 4 inch thick basement level slab poured with concrete
Future walls are breing marked and documented
Insulation downward with polystyrene board 1 inch - over top double layer Polyethylen film -  hold the pipe in place - flat meshwire - this will be a 4 inch thick main level slab poured with concrete
Test manifold inside future walls are breing marked and documented
Monolythic slab (foudations and slab are one) Insulation downward with polystyrene board 1 inch -  -  hold the pipe in place - flat meshwire - this will be a 4 inch thick main level slab poured with concrete.
Insulation detail arround future plumbing drainpipe

addsl1 addsl1 addsl1 addsl1 Types of slabs :
Concrete slab  4 to 6 inch regular
Leght weight concerte slabs 2-1/4"
Gypcrete slabs 1.5 to 1.75 inch
Thinset tpical for tiles  0.75 to 1 inch
Indoor slab - Insulation downward polystyrene board 1 inch - to hold the pipe in place - rebars  - this will be a 4 inch thick main level entrance slab poured with concrete. Salb over slab with barrier foil tapped seams and meshwire to hold piping in place. Overpour over existing salb with 2-1/4" concrete  Typical subfloor at for mainlevel slab - piping attched with plastic clamps to subfloor and will be overpoured with 1 -1/2 inch gypcrete    Typical subfloor and concrete cement board for bath room floor and  shower ares. Piping attched with plastic clamps to subfloor and will be emebdded in thin set for the tiles.  Insulation  fopr slabs :
Underneeth
thicker insulation more heatloss prevention - yes underneeth salbs there can be quite a lot of heat loss - wet soil and drainage issues will add to heat loss  
Perimeter
the most exposed area - insulation a must
Details:
Arround drain pipes and other openings - forms for footers and such - minimum moist barrier - added insualtion even better